Sl.no Description
1 Supply ,installation ,testing & commissioning of 5
loop addressable fire alarm panel with 30 minutes
battery back up , battery charger , alarm bell,
test buttons suitable for 99 devices per loop .UPS
power to be provided to panel by default
2 Active Repeater silence mute reset accept mute
evacuate and test controls with RS 485 communication
module
3 RS485 Communication module
4 Supply ,installation ,testing & commissioning of loop card
5 Supply ,installation ,testing & commissioning of
addressable type ceiling mounted heat detector
6 Supply ,installation ,testing & commissioning of
addressable type above and below ceiling mounted
smoke detector
7 Supply ,installation ,testing & commissioning of
addressable manual break glass unit including with
mounting box.
8 Supply ,installation ,testing & commissioning of
addressable electronic alarm hooters.
9 Sensor Mounting base made in India
10 Supply ,installation ,testing & commissioning of
addressable fault isolator.
11 Single Input Monitor Module, requires
M220E/SMB for surface mounting or M200E-Din for
mounting to DIN rails.
12 Supply ,installation ,testing & commissioning of
addressable control module.
13 Analogue Beam
14 Surface Mounting Kit
15 Response Indicator
CABLE REQUIRED FOR FIRE ALARM SYSTEM
1). Supply ,laying of 1100 volts stranded class 2 bare copper conductor XLPE
insulated cores laying for laid up extruded ST2 PVC I/SH single layer galvanised
steel round wire armoured and extruded FR-LSH PVC outer sheathed fire alarm
cable for fire alarm system.Cable shall be laid on ceilings and wall by providing
shaddles and clamp or on prelaid perforated cable tray.
Make: - Polycab colour Red
Polycab 1.5mm x 2core copper armoured FRLSH UG fire alarm cable
Polycab 1,5 mm x 2core Ind.Flex.M/core cable 1100v grade
DETECTOR FOR FIRE ALARM SYSTEM
SMOKE DETECTOR:-
Smoke Detector Honeywell ,Make: MorleyModel/Part Code: HMPSES2+MIB501APIV
ADDRESSABLE FDA PANEL FIRE PANEL BOQ
Make: Honeywell, Model: MORLEY - IAS ZX5SE, No of loops: 5,
1).Low profile Optical Smoke Sensor(HMPSES2): Morley
2).Sensor Mounting base for addressable detectors : Morley
3).ZXrA Active Repeater silence Mute Reset Accept Mute Evacute
4).Active Repeater Silence Mute
Reset Accept Mute Evacuate and test controls with RS 485 Communication module
5).).ZX5Se 15 loop control panel 230Vac 4 Sounder
ZX5Se 1-5 loop control panel, 230Vac, 4sounder circuits, 4 line display and networking capability,
6Amp PSU with 450mA loop capability 500 x 500x 195 mm
6) RS 485 Communication module
7) Loop Driver Card for Morley IAS Protocol ,460mA
8) Heat Sensor 58degree C EN54 part 5 Type A1 requires
9) Low Profile Optical Smoke Sensor
10) Red Add Call Point Flush Mounting Glass
11) Sensor Mounting base for Addressable detectors
12)Intelligent Wall Mounted Sounder Red
13) Input- Cum- Monitor Module : Single input monitor
14)Relay Module : Output control module , Requires M200ESMB
15) Analogue Beam
16) Surface Mount Kit for IR reflective beam
17) Isolator module : Loop isolation module ,Requires M200ESMB
18) Response indicator (SSFRI007H)
19)MCP Back box
20) ZX r-A Active Repeater , Silence ,Mute ,Reset ,Accept , Evacuate and Test Controls
.For use with DX control panels only use a 24 V dc supply .For use with ZX control panel use a
24Vdc supply and an RS 485 card.165 x 254 x 50mm(H x Wx D)
21)Loop Isolation Module ,Requires M 200E -SMB for surface mounting or M200E -DIN
for mounting to DIN rails
WORK DESCRIPTION:-
1). Supply installation testing & commissioning of 5 loop addressable fire alarm panel with
30 minutes battery back up ,battery charger , alarm bell, test buttons suitable for 99 devices
per loop . UPS power to be provided to panel by default.
2). Active Repeater silence mute reset accept mute evacuate and test controls with RS485
communication module.
3).RS 485 communication module
4). Supply installation testing & commissioning of loop card.
5)Supply installation testing & commissioning of addressable type ceiling mounted heat detector.
6)Supply installation testing & commissioning of addressable type above and below ceiling
mounted smoke dtector.
7).Supply installation testing & commissioning of addressable manual break blass unit including with mounting
box.
8).Supply installation testing & commissioning of addressable electronic alarm hooters.
9).Sensor mounting base.
10)Supply installation testing & commissioning of addressable fault isolator.
11).Single Input monitor module requires M220E/SMB for surface mounting .
12). Supply installation testing & commissioning of addressable control module.
13).Analogue beam.
14). Surface Mounting kit.
15).Response Indicator.